Air King BFQ110 Fiche d'instructions

Naviguer en ligne ou télécharger Fiche d'instructions pour Non Air King BFQ110. Air King BFQ110 Instruction Sheet Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
210572021 Rev. S 7-16 1 of 12
Exhaust Fan
BFQ, BFQW Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING:
TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
a) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
b) Do not install wall mounted fans inside the shower area.
WARNING: DO NOT USE IN KITCHENS.
WARNING: THE DUCTING FROM THIS FAN TO THE
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - OPERATING MANUAL

IMPORTANT INSTRUCTIONS -OPERATING MANUALSAVE THESE INSTRUCTIONSwww.airkinglimited.com210572021 Rev. S 7-16 1 of 12Exhaust FanBFQ, BFQW SeriesREAD AND

Page 2 - SECTION 3

www.airkinglimited.com210572021 Rev. S 7-16 10 of 12Guide de dépannage Trouble Cause Possible Solution Suggérée 1. Le ventilateur ne fonctionne p

Page 3 - SECTION 5

Installateur : Date d’installation : Endroit de l’achat : Numéro de modèle : GARANTIE LIMITÉEQUE COUVRE CETTE GARANTIE : Ce produit est garanti

Page 4

www.airkinglimited.com210572021 Rev. S 7-16 12 of 12 # de pièce # Qté. Description de remplacement 1 1 Cabinet du ventilateur

Page 5 - CUSTOMER SERVICE:

INSTALLATION INSTRUCTIONSCAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION.SECTION 1Preparing the Exhaust Fan1.

Page 6 - REPLACEMENT PARTS DIAGRAM

2. Line up the bracket on the joist so the bottom of the fan will be flush with the finished ceiling. Nail or screw the snap-in bracket in place secure

Page 7 - MODE D’EMPLOI

www.airkinglimited.com210572021 Rev. S 7-16 4 of 12Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate wh

Page 8

Installer: Installation Date: Place of Purchase: Model Number: LIMITED WARRANTYWHAT THIS WARRANTY COVERS: This product is warranted against defe

Page 9

# Qty. Description Replacement Part # 1 1 Fan Housing 5S2205001 2 1 Damper Assembly - BFQ 5S2299054 1 Damper Assembl

Page 10 - SECTION 7

INSTRUCTIONS IMPORTANTES – MODE D’EMPLOICONSERVER CES INSTRUCTIONSwww.airkinglimited.com210572021 Rev. S 7-16 7 of 12Ventilateur d’ÉvacuationSérie BFQ

Page 11 - SERVICE À LA CLIENTÈLE :

INSTRUCTIONS D’INSTALLATIONATTENTION : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.SECTION 1Pré

Page 12

SECTION 3Construction Existante - Modèles BFQ1. Positionner le cabinet contre la solive ou le montant et tracer le contour du cabinet sur le matériau