Air King AKF100 Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Ventilateurs des ménages Air King AKF100. Air King AKF100 Instructions / Assembly Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
Models:
AKF80LS, AKF100LS
www.airkinglimited.com
210572203 Rev. B 3-08
Exhaust Fan with Light
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
10. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or
shower.
WARNING: DO NOT USE IN KITCHENS
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
1 of 12
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONSREAD CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECTYOURSELF AND

Page 2 - SECTION 3

Figure 10www.airkinglimited.com210572203 Rev. B 3-08 10 of 12Figure 112. Installer la grille en pressant ensemble les deux extrémitésdes ressorts et e

Page 3 - SECTION 6

www.airkinglimited.com210572203 Rev. B 3-08 11 of 12GARANTIE LIMITÉETous les produits fabriqués par Air King Limited sont garantis pour un an à partir

Page 4

110223456789111213141516171819202122232425262728293031323334373839243635www.airkinglimited.com210572203 Rev. B 3-08 12 of 12# de pièce# Qty. Descripti

Page 5 - LIMITED WARRANTY

SECTION 4DuctingCAUTION: ALL DUCTING MUST COMPLY WITH LOCALAND NATIONAL BUILDING CODES.1. Connect the ducting to the fan’s duct collar (Figure 4). Sec

Page 6 - REPLACEMENT PARTS DIAGRAM

1b. Internal Wire Compartment: Remove the three screws holdingthe blower assembly in place and lift assembly out of housing(Figure 6). Remove the wire

Page 7 - MANUEL D’OPÉRATION

www.airkinglimited.com210572203 Rev. B 3-08 4 of 12Figure 115. Restore power and test your installation.SECTION 7Use and CareCAUTION: MAKE SURE POWER

Page 8

LIMITED WARRANTYAll products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanshipand/o

Page 9

www.airkinglimited.com210572203 Rev. B 3-08 6 of 12110REPLACEMENT PARTS DIAGRAM# Qty. Description Replacement Part #1 1 Fan Housing 5S12020332 4 Mount

Page 10 - SECTION 7

LIRE ET CONSERVER CES INSTRUCTIONSLIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZVOUS-MÊME

Page 11 - GARANTIE LIMITÉE

dissimulés ou autres utilités. Installer les traverses sur lechâssis et positionner le châssis dans le trou percéprécédemment afin qu’il soit à effleu

Page 12

1b. Compartiment de Câblage Intérieur: enlever les trois visretenant en place l’assemblage de la soufflante et souleverpour sortir l’assemblage hors d

Commentaires sur ces manuels

Pas de commentaire